pontiac Workshop Repair Guides

Pontiac Workshop Service and Repair Manuals

Camshaft Position Actuator Solenoid Valve Solenoid Replacement - Bank 1 (Right Side) Intake|Page 4089 > < Camshaft Position Actuator Solenoid Valve Solenoid Replacement - Bank 1 (Right Side) Intake|Page 4087
Page 1
background image

Variable Valve Timing Solenoid: Service and Repair
Camshaft Position Actuator Solenoid Valve Solenoid Replacement - Bank 1 (Right Side) Exhaust

CAMSHAFT POSITION ACTUATOR SOLENOID VALVE SOLENOID REPLACEMENT - BANK 1 (RIGHT SIDE) EXHAUST

Removal Procedure

1.  Remove the air cleaner assembly.
2.  Disconnect the engine wiring harness electrical connector (5) from the bank 1 exhaust camshaft position (CMP) actuator solenoid valve.

3.  Remove the CMP actuator solenoid valve bolt.
4.  Remove the CMP actuator solenoid valve.
5.  Inspect the CMP actuator solenoid valve seal and replace as necessary.

Installation Procedure

Camshaft Position Actuator Solenoid Valve Solenoid Replacement - Bank 1 (Right Side) Intake|Page 4089 > < Camshaft Position Actuator Solenoid Valve Solenoid Replacement - Bank 1 (Right Side) Intake|Page 4087