G6 V6-3.6L (2007)
1. Inspect the CMP actuator solenoid valve seal for damage. Replace the seal if necessary.
2. Install the CMP actuator solenoid valve.
3. Loosely install the CMP actuator solenoid valve bolt.
4. Connect the engine wiring harness electrical connector (7) to the bank 1 intake CMP actuator solenoid valve.
Notice: Refer to Fastener Notice.
5. Tighten the CMP actuator solenoid valve bolt.
Tighten the bolt to 10 Nm (89 lb in).
6. Position the A/C line and install the push pin retainer.
7. Install the air cleaner assembly.