G6 V6-3.6L (2007)
Notice: Refer to Fastener Notice.
2. Install the high pressure relief valve.
Tighten the valve to 8 N.m (70 lb in).
3. Install the air conditioning compressor.
4. Evacuate and recharge the refrigerant system. Refer to Refrigerant Recovery and Recharging.
5. Leak test the fittings of the component using J 39400-A.