G6 V6-3.9L (2009)
Hose/Line HVAC: Service and Repair
Air Conditioning Condenser and Air Conditioning Evaporator Tube Replacement
Air Conditioning Condenser and Air Conditioning Evaporator Tube Replacement
Special Tools
J 39400-A Halogen Leak Detector
Removal Procedure
1. Recover the refrigerant. Refer to Refrigerant Recovery and Recharging (See: Heating and Air Conditioning/Service and
Repair/Procedures/Refrigerant Recovery and Recharging).
2. Remove the refrigerant pressure sensor wire harness connector.
3. Remove the refrigerant pressure sensor.
4. Remove the liquid line bracket bolt.
5. Remove the air cleaner assembly. Refer to Air Cleaner Assembly Replacement (NU6) (See: Filters/Air Cleaner Housing/Service and Repair)Air
Cleaner Assembly Replacement (NT7) (See: Filters/Air Cleaner Housing/Service and Repair).
6. Remove the surge tank from the surge tank bracket.
7. Remove the suction hose and liquid line nut from the thermal expansion valve (TXV).
8. Remove the suction hose and liquid line from the TXV.