pontiac Workshop Repair Guides

Pontiac Workshop Service and Repair Manuals

All Technical Service Bulletins: > < Instrument Panel - Noise Coming From Center Area
Page 2
background image

4.

Apply RTV silicone rubber adhesive sealant to the inside of the 1" piece of rubber hose.

5.

Set mode lever on control panel to defrost position. This will expose the edge of the defroster valve.

FIGURE 3

6.

Reach through the duct opening in the module assembly and push the 1" piece of hose with sealant onto the exposed edge of the metal defroster
door. SEE FIGURE 3.

CAUTION: Ample cure time for RTV sealant must be allowed to insure rubber hose adheres to the valve.

7.

Reassemble floor air outlet duct assembly and right side insulator assembly.

Warranty Information:

Labor Operation:

T4636

Labor Time

:

.4 hrs.

All Technical Service Bulletins: > < Instrument Panel - Noise Coming From Center Area