pontiac Workshop Repair Guides

Pontiac Workshop Service and Repair Manuals

All Technical Service Bulletins for Evaporator Case: > < A/C - Odors Emitted at Start Up in Hot Humid Climates|Page 7093
Page 5
background image

37.

Finish the installation of the dash components and close out panels.

Afterblow Module Test

TO TEST THE AFTERBLOW MODULE USE THE FOLLOWING PROCEDURE

1.

Start the engine.

2.

Turn the A/C system to engage the compressor.

3.

Connect a jumper wire to apply battery voltage to the open cavity Pin H (Green Wire) of the afterblow module for at least thirty (30 seconds with
the compressor engaged.

4.

Turn the ignition key off.

5.

The blower should come on after approximately ten (10) seconds for one (1) second and then go off.

6.

Disconnect the jumper wire.

NOTICE:

The afterblow module is not compatible with some non-factory installed theft alarm systems. The module current draw at key off
position could trigger alarms that sense battery voltage changes or current drain.

ADVISE OWNER that the afterblow module will enable the blower motor to run at high speed for five (5) minutes approximately fifty (50) minutes after
the vehicle ignition is turned off, if the A/C compressor was engaged for at least four (4) minutes or more during last ignition cycle.

Labor Operation:

T6235

Labor Time

:  2.8 Hours

If the air inlet screen needs to be sealed, use add time of 0.2 hours.

All Technical Service Bulletins for Evaporator Case: > < A/C - Odors Emitted at Start Up in Hot Humid Climates|Page 7093