pontiac Workshop Repair Guides

Pontiac Workshop Service and Repair Manuals

Auxiliary Power Outlet|Testing and Inspection > < O/H Console Accessory Power Receptacle|Page 7982
Page 1
background image

Auxiliary Power Outlet: Description and Operation

Voltage is applied through AUX/CNSL Fuse at all times to the roof console accessory power receptacle through circuit 2540. Ground is provided to the
roof console accessory power receptacle through circuit 350 from G302. Voltage is applied through CIG LTR Fuse at all times to the floor console
accessory power receptacle through circuit 440. Ground is provided to the floor console accessory power receptacle through circuit 150 from G200.
Whenever an accessory is inserted into either the roof or floor accessory power receptacle the circuit is completed and power is applied to the accessory.

Voltage is also applied through CIG LTR Fuse at all times to the cigar lighter through circuit 440. Ground is provided to the cigar lighter through circuit
1450 from G200. The cigar lighter has a heating element that, when pushed in, completes the circuit to ground and begins to heat up. When the element
is sufficiently heated, the cigar lighter pops out and opens the circuit.

Voltage is also applied to the auxiliary power drop connector through CIG LTR Fuse at all times and also the POWER DROP Fuse when the ignition
switch is set to RUN. The power drop connector can he used for a more permanent connection of an accessory. Ground will also be applied to the
accessory through circuit 1450.

Auxiliary Power Outlet|Testing and Inspection > < O/H Console Accessory Power Receptacle|Page 7982