Underhood Electrical Center #1

CIRCUIT DESCRIPTION

Power for the fan motors comes from 60 amp maxifuse elements to the fan relays. The relays are energized when current flows to ground through
the PCM (Quad-Driver).

Fan 1 relay
The PCM energizes the relay through terminal "A2" when the engine coolant temperature reaches 106°C (223°F) or when A/C is requested.

Fan 2 relay
The fan 2 relay is energized by the PCM if the A/C refrigerant pressure sensor reaches 240 psi or the engine coolant temperature reaches 108°C
(226°F).

CHART TEST DESCRIPTION

Number(s) below refer to circled number(s) on the diagnostic chart.

1. Verifies power feed to fan 2 relay at right side underhood electrical center terminals "B8" and "B10."
2. Jumpering terminals "B10" and "C8" bypasses the fan 2 relay. If right side fan runs, the relay is faulty.