pontiac Workshop Repair Guides

Pontiac Workshop Service and Repair Manuals

Air Duct > < HVAC System - Automatic|Page 8396
Page 6
background image

1. Position the temperature actuator, then align the slots in the electric actuator driver to the flats on the temperature valve shaft.
2. Slide the electric actuator driver onto the shaft, while aligning the actuator locating hole to the forward alignment pin on the HVAC module case.

The actuator driver should completely seat onto the temperature valve shaft and the mounting holes should be flush with the mounting bosses on
the HVAC module case.

NOTE:  Refer to Fastener Notice in Service Precautions.

3. Install the mounting bolts to the temperature actuator.

Tighten
Tighten the temperature actuator bolts to 1.5 N.m (13 lb in).

4. Connect the electrical connector to the temperature valve electric actuator.
5. Install the knee bolster. 
6. Install the left instrument panel insulator. 

Air Duct > < HVAC System - Automatic|Page 8396