Control Module HVAC > < HVAC - Automatic|Page 13342
Page 2
background image

Tighten the screws to 2 N.m (18 lb in).

4. Install the I/P center compartment.
5. Install the I/P accessory trim plate.

Important:  Do not adjust any controls on the HVAC control module while the HVAC control module is self calibrating. If interrupted,
improper HVAC performance will result. The engine must be running for proper calibration to occur.

6. Start and allow the engine to run for at least one minute.

Control Module HVAC > < HVAC - Automatic|Page 13342