pontiac Workshop Repair Guides

Pontiac Workshop Service and Repair Manuals

Generator Brace Replacement (L26)|Page 11302 > < Generator Brace Replacement (L26)
Page 1
background image

Alternator: Service and Repair
Generator Replacement (RPOs L26/L32)

Generator Replacement (RPOs L26/L32)

Removal Procedure

1. Disconnect the negative battery cable.
2. Remove the drive belt.
3. Remove the generator rear brace.
4. Remove the bolts (1, 3) and the stud (2) from the generator.
5. Disconnect the electrical connector from the generator.
6. Position aside the protective boot from the generator output BAT terminal for access.
7. Remove the generator output BAT terminal nut and remove the positive battery lead from the generator.
8. Remove the generator.

Installation Procedure

1. Position the generator to the engine.

Notice:  Refer to Fastener Notice in Service Precautions.

2. Install the positive battery lead to the generator.
3. Install the generator output BAT terminal nut.

Tighten the nut to 20 N.m (15 lb ft).

4. Install the protective boot to the generator output BAT terminal.
5. Connect the electrical connector to the generator.

Important:  Do not tighten the stud.

6. Install the generator stud (2) to the generator bracket.

Important:  Do not tighten the bolts.

Generator Brace Replacement (L26)|Page 11302 > < Generator Brace Replacement (L26)