pontiac Workshop Repair Guides

Pontiac Workshop Service and Repair Manuals

Air Temperature Actuator Replacement|Page 6275 > < Air Temperature Actuator Replacement|Page 6273
Page 1
background image

Air Door Actuator / Motor: Service and Repair
Mode Actuator Replacement

MODE ACTUATOR REPLACEMENT

REMOVAL PROCEDURE

1. Remove the right instrument panel (I/P) insulator.
2. Remove the I/P compartment.
3. Remove the screws that secure the mode actuator (1) to the HVAC module assembly.
4. Remove the mode actuator from the HVAC module assembly.
5. Disconnect the electrical connector from the mode actuator.

INSTALLATION PROCEDURE

1. Position the mode actuator, aligning the slots in the electric actuator drive to the flats on the shaft.
2. Align the locating hole to the alignment pin on the HVAC module assembly.
3. Slide the actuator drive completely onto the shaft, with the mounting holes flush with the mounting screw holes on the HVAC module assembly.

NOTE:  Refer to Fastener Notice in Service Precautions.

4. Install the screws to the mode actuator (1).

Tighten
Tighten the screws to 1.5 N.m (13 lb in).

Air Temperature Actuator Replacement|Page 6275 > < Air Temperature Actuator Replacement|Page 6273