pontiac Workshop Repair Guides

Pontiac Workshop Service and Repair Manuals

Service Port HVAC|Service and Repair|Page 6578 > < Refrigerant Pressure Sensor / Switch, HVAC|Locations|Page 6574
Page 1
background image

Service Port HVAC: Service and Repair

SERVICE PORTS REPLACEMENT

TOOLS REQUIRED

J 39037 Charge Valve Octagon Socket

REMOVAL PROCEDURE

1. Remove the service port cap.
2. Recover the refrigerant. Refer to Refrigerant Recovery and Recharging.
3. Use the J 39037 to remove the service port.

INSTALLATION PROCEDURE

1. Replace the O-ring.

NOTE:  Refer to Fastener Notice in Service Precautions.

2. Install the service port valve.

Tighten
Tighten the valve to 11 N.m (98 lb in).

3. Evacuate and charge the system. Refer to Refrigerant Recovery and Recharging.
4. Leak test the A/C service port. Refer to Leak Testing.

Service Port HVAC|Service and Repair|Page 6578 > < Refrigerant Pressure Sensor / Switch, HVAC|Locations|Page 6574