pontiac Workshop Repair Guides

Pontiac Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 4468 > < Diagram Information and Instructions|Page 4466
Page 30
background image

-

Yazaki has a wedge or arrow shape, similar to that shown.

Delphi Connectors (Micro .64)

DELPHI CONNECTORS (MICRO.64)

TOOLS REQUIRED

J-38125 Terminal Repair Kit

IMPORTANT:  When probing female 0.64 terminals, it is important to use the correct adapter. There have been some revisions to the test adapter for
0.64 terminals. The proper adapter for 0.64 terminals is the J 35616-64B which has a tin terminal and a blue wire between the base and tip. Failure to
use the proper test adapter may result in damage to the terminal being tested and improper diagnosis.

REMOVAL PROCEDURE

Follow the steps below in order to remove terminals from Micro 64 connectors.

1. Locate the lever lock on the wire dress cover. While depressing the lock, pull the lever over and past the lock. The lever lock may be located on

the top or sides of the wire dress cover.

Diagram Information and Instructions|Page 4468 > < Diagram Information and Instructions|Page 4466