GTO V8-6.0L VIN U (2005)
2. Install the water pump inlet with thermostat.
Notice: Refer to Fastener Notice in Service Precautions.
3. Install the water pump inlet bolts.
Tighten the water pump inlet bolts to 14 Nm (10 ft. lbs.).
4. Install the outlet hose to the water pump inlet.
5. Position the outlet hose clamp at the water outlet.
6. Fill the cooling system.