Hazard Warning Switch: Service and Repair

HAZARD WARNING SWITCH REPLACEMENT

REMOVAL PROCEDURE

1. Remove the instrument panel center trim panel (1).
2. Remove the 4 screws (2) attaching the instrument panel center air outlet assembly (3) to the instrument panel center trim panel (1).
3. Press the 2 retaining tabs securing the hazard warning switch (4) to the air outlet housing (2) and remove the hazard warning switch (4).

INSTALLATION PROCEDURE

1. Install the hazard warning switch (4) to the center air outlet housing (3), making sure the 2 retaining tabs are engaged.
2. Install the center air outlet (3) to the instrument panel center trim panel (1).
3. Install the 4 screws (2) securing the center air outlet panel (3) to the instrument panel center trim panel (1).

NOTE:  Refer to Fastener Notice in Service Precautions.

Tighten the 4 screws to 2 N.m (18 lb in).

4. Install the instrument panel center trim panel (1).