pontiac Workshop Repair Guides

Pontiac Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 5527 > < Diagram Information and Instructions|Page 5524
Page 1
background image

Blower Motor: Initial Inspection and Diagnostic Overview

1. 

Check HTR-A/C Fuse by visual inspection.

2. 

Check Fusible Link B by visual inspection.

3. 

Check that grounds are clean and tight.

4. 

Check that the Blower Motor connectors and High Blower Relay are mated correctly and firmly seated.

5. 

If blower runs all of the time with Ignition Switch OFF, replace the High Blower Relay.

6. 

If blower runs all of the time with the Ignition Switch in RUN and Mode Selector OFF, replace the Mode Selector.