Audible Warning Device: Description and Operation
Key-In-Ignition Chime

Voltage is applied at all times to term A of the Multi-function Alarm Module through the CTSY Fuse. When the key is in the ignition and LH front door
is open, term J of the Multi-function Alarm Module is grounded. This sounds the chime.