Hose/Line HVAC: Service and Repair
Discharge Hose

DISCHARGE HOSE REPLACEMENT

TOOLS REQUIRED

J 39400-A Halogen Leak Detector

REMOVAL PROCEDURE

1. Remove the air cleaner assembly. 
2. Recover the refrigerant from the A/C system. 

3. Remove the discharge hose to condenser nut.
4. Disconnect the discharge hose from the condenser.
5. Cap or tape the discharge port on the condenser.

IMPORTANT:Cap or tape the open A/C hoses and A/C refrigerant component immediately to prevent A/C system contamination.

6. Remove the discharge hose to compressor nut.
7. Disconnect the discharge hose from the compressor.
8. Cap or tape the compressor discharge port.
9. Remove the discharge hose.

10. Remove and discard the sealing washers.

INSTALLATION PROCEDURE

1. Install a new sealing washer onto the compressor side of the discharge hose. 
2. Install the discharge hose.
3. Remove the cap or tape from the compressor discharge port.

Discharge Hose|Page 7197 > < Hose/Line HVAC|Service Precautions