Montana AWD V6-3.4L VIN E (2004)
Housing Assembly HVAC: Service and Repair
HVAC Module Assembly Replacement
HVAC MODULE ASSEMBLY REPLACEMENT
TOOLS REQUIRED
J 39400-A Halogen Leak Detector
REMOVAL PROCEDURE
1. Recover the refrigerant from the A/C system.
2. Drain the cooling system.
3. Remove the left wiper arm linkage nuts.
Reposition the left wiper arm linkage for access.
4. Set the HVAC controls in the vent setting to close the defroster door.
IMPORTANT:The defroster door must be closed to allow clearance during defroster duct removal.
5. Remove the blower motor.
6. Disconnect the electrical connector from the blower motor resistor.
7. Disconnect the electrical connector from the evaporator temperature sensor.
8. Disconnect all of the HVAC actuator electrical connectors.
9. Remove the IP carrier.