3. Install the evaporator inlet tube.
4. Connect the electrical connector on the evaporator outlet tube bracket.

Notice:  Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may
damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.

5. Install the evaporator outlet tube bracket bolt.

Tighten
Tighten the bolt to 5.5 Nm (48.7 lb in).

6. Remove the cap or tape from the auxiliary evaporator inlet tube.
7. Connect the auxiliary evaporator inlet tube to the evaporator inlet tube.

Tighten
Tighten the nut to 27 Nm (20 lb ft).

8. Remove the cap or tape from the condenser.
9. Connect the evaporator inlet tube to the condenser.

10. Install the evaporator inlet tube to condenser fitting bolt.

Tighten
Tighten the bolt to 16 Nm (12 lb ft).

11. Remove the cap or tape from the TXV.
12. Connect the evaporator inlet tube to the evaporator outlet tube.
13. Connect the evaporator inlet and outlet tubes to the TXV.

Discharge Hose|Page 2375 > < Discharge Hose|Page 2373