pontiac Workshop Repair Guides

Pontiac Workshop Service and Repair Manuals

Auxiliary Blower Motor Replacement (Without RPO Code E59)|Page 14796 > < Auxiliary Blower Motor|Diagrams
Page 1
background image

Auxiliary Blower Motor: Service and Repair
Auxiliary Blower Motor Replacement (Without RPO Code E59)

Auxiliary Blower Motor Replacement (Without E59)

Removal Procedure

1. Remove the inflator air valve opening cover.

2. Remove the screws from the hinged cover.
3. Remove the cover from the rear trim panel.
4. Release the tabs and pull out the trim panel.
5. Disconnect the auxiliary blower motor electrical connector.
6. Disconnect the auxiliary blower motor resistor electrical connector.
7. Disconnect the auxiliary air temperature actuator electrical connector.

8. Remove the auxiliary blower motor mounting screws.
9. Remove the auxiliary blower motor from the blower motor housing.

Installation Procedure

1. Install the auxiliary blower motor to the blower motor housing.

Notice:  Refer to Fastener Notice.

2. Install the auxiliary blower motor mounting screws.

Auxiliary Blower Motor Replacement (Without RPO Code E59)|Page 14796 > < Auxiliary Blower Motor|Diagrams