Montana SV6 V6-3.9L (2007)
Blower Motor Relay: Service and Repair
Auxiliary Blower Motor Relay Replacement
Removal Procedure
1. Remove the left lower quarter trim panel.
2. Disconnect blower motor relay electrical connector.
3. Remove the blower motor relay bolts/screws.
4. Remove the blower motor relay.
Installation Procedure
1. Install the blower motor relay.
2. Connect the blower motor relay electrical connector.
Notice: Refer to Fastener Notice.
3. Install the blower motor relay bolts/screws.
The bolts/screws to 1.6 N.m (14 lb in).
4. Install the left lower quarter trim panel.