pontiac Workshop Repair Guides

Pontiac Workshop Service and Repair Manuals

Evaporator Core > < Condenser HVAC|Service and Repair|Page 4339
Page 1
background image

Control Assembly: Service and Repair

VEHICLES LESS AUTOMATIC TEMPERATURE CONTROL 

1.

Disconnect battery ground cable.

2.

Remove instrument panel trim panel(s) to expose control unit retaining screws.

3.

Remove control unit retaining screws, then carefully draw unit out of instrument panel.

4.

Disconnect vacuum and electrical connections, then disconnect temperature control cable.

5.

Reverse procedure to install. 

Evaporator Core > < Condenser HVAC|Service and Repair|Page 4339