6. Remove the fluid passage sleeves only if replacement of the sleeves is necessary.

Installation Procedure

1. Install NEW fluid passage sleeves if previously removed.

2. Install the control valve body accumulator assembly (1) and manual shaft detent spring (2) to the transmission.
3. Install the manual shaft detent spring bolts (3) and hand tighten.

4. Confirm that the manual shift shaft detent lever locating pin (2) is properly engaged with the manual valve link (1).
5. Confirm that the detent spring roller (4) is properly engaged with the manual shift shaft switch (3).