Sunfire L4-144 2.4L DOHC VIN T SFI (2001)
Accumulator HVAC: Service and Repair
ACCUMULATOR REPLACEMENT
TOOLS REQUIRED
J 39400-A Halogen Leak Detector
REMOVAL PROCEDURE
1. Recover the refrigerant. Refer to Refrigerant Recovery and Recharging.
2. Raise and support the vehicle. Refer to Lifting and Jacking the Vehicle.
3. Remove the cruise control bracket. Position aside the bracket (if equipped).
4. Remove the refrigerant tubes from the accumulator (1). Discard the O-ring seals.
5. Remove the accumulator bracket (3).
6. Remove the accumulator (1) from the vehicle.
INSTALLATION PROCEDURE
1. Install the accumulator (1).
NOTE: Refer to Fastener Notice in Service Precautions.
2. Install the accumulator bracket (3) clamp.
Tighten
Tighten the bolt to 8 N.m (71 lb in).