pontiac Workshop Repair Guides

Pontiac Workshop Service and Repair Manuals

Air Door, HVAC > < Accumulator HVAC|Specifications|Page 6537
Page 2
background image

2. Install the accumulator bracket (3) clamp.

Tighten
Tighten the bolt to 8 N.m (71 lb in).

3. Install new O-ring seals to refrigerant lines.
4. Install the refrigerant lines to the accumulator.
5. Install the accumulator tube to accumulator and compressor tube to accumulator fitting nuts

Tighten
Tighten nuts to 35 N.m (26 lb ft).

6. Position the bracket holding the PCM Module on to the shock tower.
7. Install the bracket nuts holding the PCM Module on to the shock tower.

Tighten
Tighten the PCM bracket nuts to 10 N.m (89 lb in).

8. Reposition the cruise control bracket if equipped.
9. Evacuate and recharge the A/C system. Refer to Refrigerant Recovery and Recharging.

10. Leak test the fittings of the component using the J 39400-A.

Air Door, HVAC > < Accumulator HVAC|Specifications|Page 6537