Compressor Control Switches Removal (V5 - Conventional Mount)
TOOLS REQUIRED
^
J 5403 Snap Ring Pliers
^
J 9553-01 O-Ring Remover
^
J 39500-B ACR4 - Black Shroud
1. Recover the refrigerant using the J 39500-B.
2. Disconnect the electrical connector from the switch (3 or 4) in the rear head of the compressor.
3. Remove the switch retaining ring using the J 5403.
4. Remove the switch (3 or 4) from the compressor.
NOTE: If the existing switch will be reinstalled in the compressor, a new O-ring seal must be used and preferably a new retainer should also be used.
A new switch kit has the O-ring and retainer ring included.
5. Remove the old O-ring seal from the switch cavity using the J 9553-01.