pontiac Workshop Repair Guides

Pontiac Workshop Service and Repair Manuals

Control Module HVAC > < Diagram Information and Instructions|Page 12967
Page 2
background image

Tighten the screws to 1.5 N.m (13 lb in).

NOTE:  Refer to Fastener Notice.

3. Connect the electrical connectors to the HVAC control module.
4. Install the center trim bezel to the instrument panel. 
5. Calibrate the mode actuators by simultaneously pushing the A/C and RECIRC buttons on the HVAC control module 3 times each, within 2

seconds of initial push.

IMPORTANT:  Any time a mode actuator or the HVAC control module is replaced, the HVAC control module must be calibrated to ensure proper
air distribution.

6. Calibrate the mode actuators by simultaneously pushing the A/C and RECIRC buttons on the HVAC control module 3 times each, within 2

seconds of initial push.
-

The A/C and RECIRC button LED's will flash while this calibration is taking place.

-

The calibration will take anywhere between 10-30 seconds depending on battery voltage.

-

The LED's will quit flashing when the calibration is complete.

7. Cycle the ignition and verify proper operation.