pontiac Workshop Repair Guides

Pontiac Workshop Service and Repair Manuals

A/C - Poor Performance/Not Cold Enough|Page 13100 > < A/C - Poor Performance/Not Cold Enough|Page 13098
Page 1
background image

Expansion Valve: Service and Repair

THERMAL EXPANSION VALVE REPLACEMENT

TOOLS REQUIRED

J 39400-A Halogen Leak Detector

1. Recover the refrigerant. Refer to Refrigerant Recovery and Recharging.

2. Remove the evaporator outlet hose and liquid line retainer plate nut from the TXV.

IMPORTANT:  When removing the thermal expansion valve (TXV), keep dirt and foreign material from getting on or into the sealing surfaces.
Clean tools and a clean work area are important for proper service. The TXV seal area should be cleaned before any repairs are performed. The parts
must be kept clean at all times and any parts to be assembled should be cleaned with a non-petroleum based solvent and dried with air. Use only lint
free cloths to wipe parts. Do not allow solvent to enter evaporator or hoses.

3. Remove the evaporator outlet hose and liquid line from the TXV.
4. Remove and discard the sealing washers from the evaporator outlet hose and liquid line.
5. Install protective caps to the evaporator outlet hose and the liquid line to prevent contamination and desiccant saturation. 

A/C - Poor Performance/Not Cold Enough|Page 13100 > < A/C - Poor Performance/Not Cold Enough|Page 13098