pontiac Workshop Repair Guides

Pontiac Workshop Service and Repair Manuals

Coolant Reservoir > < Heater Inlet Pipe Replacement|Page 3796
Page 10
background image

Installation Procedure

1. Apply sealant GM P/N 12345493 (Canadian P/N 10953488) or equivalent to the end of the thermal bypass pipe where the pipe is pressed into the

intake manifold.

2. Install the thermal bypass pipe using J 21882  .

Notice:  Refer to Fastener Notice   .

3. Install the thermal bypass pipe bolt.

Tighten the bolt to 10 N.m (89 lb in).

4. Install the thermal bypass hose. Refer to Thermal Bypass Hose Replacement  (See: ) .
5. Install the upper intake manifold. Refer to Upper Intake Manifold Replacement  (See: Engine/Intake Manifold/Service and Repair) .
6. Fill the engine with coolant. Refer to Cooling System Draining and Filling (LNJ Static Fill)  (See: Service and Repair)Cooling System Draining

and Filling (LNJ GE 47716 Fill)  (See: Service and Repair)Cooling System Draining and Filling (LY7 Static Fill)  (See: Service and Repair
)Cooling System Draining and Filling (LY7 GE 47716 Fill)  (See: Service and Repair) .