Vibe L4-1.8L (2008)
Canister Purge Solenoid: Service and Repair
Evaporative Emission Canister Purge Solenoid Valve Replacement
Removal Procedure
1. Disconnect the electrical connector (1) from the evaporative emission (EVAP) canister purge valve (2).
2. Disconnect the 2 vacuum hoses (4) from the EVAP canister purge valve (2).
3. Remove the EVAP canister purge valve from the air inlet duct hose.
4. Inspect the EVAP canister purge valve and the EVAP purge system for carbon particle contamination before replacing the EVAP canister purge
valve.
Installation Procedure
1. Insert the locator pin (3) of the purge valve into the mounting hole on the air inlet duct.
2. Connect the 2 vacuum hoses (4) to the EVAP canister purge valve (2).
3. Connect the electrical connector (1) to the EVAP canister purge valve (2).