pontiac Workshop Repair Guides

Pontiac Workshop Service and Repair Manuals

Variable Valve Timing Pressure Switch|Locations|Page 1797 > < Variable Valve Timing Pressure Switch|Locations|Page 1795
Page 2
background image

8. Remove the the rocker arm oil pressure switch (2) from the rocker arm oil control solenoid housing (1).

INSTALLATION PROCEDURE

1. Install the the rocker arm oil pressure switch (2) into the rocker arm oil control solenoid housing (1).

NOTE:  Refer to Component Fastener Tightening Notice in Service Precautions.

Tighten
Tighten the switch to 13 N.m (9.5 lb ft).

2. Connect the electrical connector to the rocker arm oil pressure switch.

3. Connect the PCV hose (1) and the PCV breather hose (2) to the engine.
4. Connect the EVAP hoses.