pontiac Workshop Repair Guides

Pontiac Workshop Service and Repair Manuals

A/C - Musty Odors Emitted From (HVAC) System|Page 6018 > < A/C - Musty Odors Emitted From (HVAC) System|Page 6016
Page 2
background image

4. Remove the four bolts and the blower motor upper case.
5. Remove the bolts and the evaporator case cover.
6. Remove the evaporator.
7. Remove the two bolts and expansion valve from the evaporator.

INSTALLATION PROCEDURE

NOTE:  Refer to Fastener Notice in Service Precautions.

IMPORTANT:  If the evaporator was replaced add 60 ml (2.0 fl oz) of compressor oil.

Install new O-rings lubricated with 525 viscosity mineral oil.

1. Install the expansion valve to the evaporator. Secure with the two bolts.

Tighten
Tighten the bolts to 5.4 N.m (48 lb in).

2. Install the evaporator to the HVAC module assembly
3. Install the evaporator case cover to the HVAC module assembly. Secure with the bolts.

Tighten
Tighten the bolts to 10 N.m (89 lb in).

4. Install the four bolts and the blower motor upper case.

A/C - Musty Odors Emitted From (HVAC) System|Page 6018 > < A/C - Musty Odors Emitted From (HVAC) System|Page 6016