8. Disconnect the electrical connector (1) from the camshaft position (CMP) actuator solenoid valve (2).
9. Remove the fastener retaining the CMP actuator solenoid valve (1) to the cylinder head.
10. Remove the CMP actuator solenoid valve (1) and the O-ring (2) from the cylinder head.
INSTALLATION PROCEDURE
1. Install a new O-ring (2) and the CMP actuator solenoid valve (1) into the cylinder head.
2. Secure the CMP actuator solenoid valve with the fastener.
NOTE: Refer to Fastener Notice in Service Precautions.