pontiac Workshop Repair Guides

Pontiac Workshop Service and Repair Manuals

Procedures|Page 7518 > < Audible Warning Device Control Module|Locations|Page 7515
Page 1
background image

Audible Warning Device Control Module: Procedures

MULTIFUNCTION ALARM MODULE REPLACEMENT

REMOVAL PROCEDURE

1. Disconnect the negative battery cable.

CAUTION:  Refer to Battery Disconnect Caution in Service Precautions.

2. Remove the screws from the junction block and position the junction block in order to gain access to the multifunction alarm module.

IMPORTANT:  The multifunction alarm module is located under the instrument panel on the drivers side.

3. Disconnect the multifunction alarm module electrical connector.
4. Disconnect the multifunction alarm module (1) from the rear of the junction block (2).

INSTALLATION PROCEDURE

1. Install the multifunction alarm module (1) to the rear of the junction block (2).
2. Connect the multifunction alarm module electrical connector.
3. Reposition the junction block back into position. Secure the junction block with the screws.
4. Connect the negative battery cable.

Procedures|Page 7518 > < Audible Warning Device Control Module|Locations|Page 7515