Vibe FWD L4-2.4L (2009)
6. Connect the A/C line.
*
For compression style fittings use a back up wrench on the fitting (2) and tighten the fitting nut (1) to specification.
*
For banjo style fittings install the bolt retaining the banjo type fitting and tighten to specification.
7. Evacuate and recharge the A/C system. Refer to Refrigerant Recovery and Recharging (See: Service and Repair/Refrigerant Recovery and
Recharging).
8. Leak test the fittings of the component using J 39400-A .