J 39200  Digital Multimeter

Perform the following procedures while wiggling the harness from side to side. Continue this at convenient points (about 6 inches apart) while watching
the test equipment.

*

Testing for Short to Ground   (See: Testing and Inspection/Component Tests and General Diagnostics)

*

Testing for Continuity   (See: Testing and Inspection/Component Tests and General Diagnostics)

*

Testing for a Short to Voltage   (See: Testing and Inspection/Component Tests and General Diagnostics)

If the fault is not identified, perform the procedure below using the MIN MAX feature on the J 39200   DMM. This feature allows you to manipulate the
circuit without having to watch the J 39200  . The J 39200   will generate an audible tone when a change is detected.

Note:  The J 39200   must be used in order to perform the following procedure since the J 39200   can monitor current, resistance or voltage while
recording the minimum (MIN), and maximum (MAX) values measured.

1. Connect the J 39200   to both sides of a suspected connector (still connected), or from one end of a suspected circuit to the other. Refer to

Troubleshooting with a Digital Multimeter   (See: Testing and Inspection/Component Tests and General Diagnostics) for information on
connecting the J 39200   to the circuit.

2. Set the rotary dial of the J 39200   to the V (AC) or V (DC) position.
3. Press the range button of the J 39200   in order to select the desired voltage range.
4. Press the MIN MAX button of the J 39200  . The J 39200   displays 100 ms RECORD and emits an audible tone (beep). 

Note:  The 100 ms RECORD mode is the length of time an input must stay at a new value in order to record the full change.

5. Simulate the condition that is potentially causing the intermittent connection, either by wiggling the connections or the wiring, test driving, or

performing other operations. Refer to Inducing Intermittent Fault Conditions   (See: Testing and Inspection/Component Tests and General
Diagnostics).

6. Listen for the audible Min Max Alert which indicates that a new minimum or maximum value has been recorded.
7. Press the MIN MAX button once in order to display the MAX value and note the value.
8. Press the MIN MAX button again in order to display the MIN value and note the value.
9. Determine the difference between the MIN and MAX values. 

*

If the variation between the recorded MIN and MAX voltage values is 1 V or greater an intermittent open or high resistance condition exists.
Repair the condition as necessary.

*

If the variation between the recorded MIN and MAX voltage values is less than 1 V, an intermittent open or high resistance condition does not
exist.

Testing for Intermittent Conditions and Poor Connections

Testing for Intermittent Conditions and Poor Connections

Tools Required

*

J 35616  GM-Approved Terminal Test Kit

*

J-38125  Terminal Repair Kit 

*

J 42675  Flat-Wire Probe Adapter

Most intermittent conditions are caused by faulty electrical connections or wiring. Inspect for the following items:

*

Wiring broken inside the insulation

*

Poor connection between the male and female terminal at a connector.

*

Poor terminal to wire connection-Some conditions which fall under this description are poor crimps, poor solder joints, crimping over the wire
insulation rather than the wire itself and corrosion in the wire to terminal contact area, etc.

*

Wire insulation which is rubbed through-This causes an intermittent short as the bare area touches other wiring or parts of the vehicle.

*

Refer to Inducing Intermittent Fault Conditions   (See: Testing and Inspection/Component Tests and General Diagnostics) in order to duplicate the
conditions required in order to verify the complaint.

*

Refer to Testing for Electrical Intermittents   (See: Testing and Inspection/Component Tests and General Diagnostics) for test procedures to detect
intermittent open, high resistance, short to ground, and short to voltage conditions.

*

Refer to Scan Tool Snapshot Procedure   (See: Testing and Inspection/Component Tests and General Diagnostics) for advanced intermittent
diagnosis.

Testing for Proper Terminal Contact

It is important to test terminal contact at the component and any inline connectors before replacing a suspect component. Mating terminals must be
inspected to ensure good terminal contact. A poor connection between the male and female terminal at a connector may be the result of contamination or
deformation.