Vibe FWD L4-2.4L (2009)
Note:
*
Use new O-rings lubricated with 525 viscosity mineral oil.
*
Hold the A/C refrigerant pressure switch mount with an open end wrench to avoid bending the liquid line.
1. Install the A/C refrigerant pressure switch (2).
Tighten the A/C refrigerant pressure switch (2) to 11 Nm (8.0 lb ft).
2. Connect the A/C refrigerant pressure switch electrical connector (1).
3. Evacuate and recharge the refrigerant system. Refer to Refrigerant Recovery and Recharging (See: Heating and Air Conditioning/Service and
Repair/Refrigerant Recovery and Recharging).
4. Operate the A/C system and check for leaks. Refer to Leak Testing (See: Heating and Air Conditioning/Testing and Inspection/Component Tests
and General Diagnostics/Leak Testing).