Description

11. Apply 60/40 rosin core solder to the opening in the back of the clip. Follow the manufacturer's instructions for the solder equipment.

Description

12. Tape the splice. Roll on enough tape in order to duplicate the thickness of the insulation on the existing wires.

Description

13. Additional tape can be applied to the wire if the wire does not belong in a conduit or another harness covering. Use a winding motion in order to

cover the first piece of tape.

Splicing Copper Wire Using Splice Sleeves

Splicing Copper Wire Using Splice Sleeves

Special Tools

J-38125  Terminal Repair Kit

Note:  Use only DuraSeal splice sleeves. Other splice sleeves may not protect the splice from moisture or provide a good electrical connection.

Use DuraSeal splice sleeves to form a one-to-one splice on all types of insulation except tefzel and coaxial. Use DuraSeal splice sleeves where there are
special requirements such as moisture sealing. Follow the instructions below in order to splice copper wire using DuraSeal splice sleeves.