Page 3
background image

12. In the menu Write in data ">>", the data read-out is installed.
13. System Tester displays Codes successfully written in. Press ">>".
14. Change to the Coding menu and compare the coding with the vehicle equipment. Recode if necessary.
15. Read out fault memory and, if necessary, erase it.

Coding the power windows motor (door control unit)

WARNING:

Sudden voltage interruption of the power supply to the control module.

-

Destruction of the control module.
-

During programming, it is essential to guarantee the power supply for the Porsche System tester. It is essential to connect a battery charger
with a current rating of at least 40 A to the vehicle battery.

-

Prior to disconnecting the control module, switch off the ignition and remove the ignition key.

NOTE:  The PIWIS tester 9718 instructions take precedence and in the event of a discrepancy these are the instructions that must be followed.
Deviations may occur with later software versions.

The procedure described here has been structured in general terms; different text or additions may appear in the PIWIS tester 9718.

NOTE:  The procedure described must be applied when a control unit has to be replaced and the tester function Control unit replacement cannot be
used.

1. Connect the PIWIS tester 9718 to the vehicle and start it. Switch on the ignition ">>"  Continue.
2. Select the vehicle type.
3. Switch to the Special functions menu and perform the vehicle handover using the "F8" key.
4. In the Special functions menu, erase All fault memories by pressing ">>".
5. Carry out automatic search of control units.
6. Using the ">>" key, move from the vehicle type to the list of control units.
7. Select Door and press the ">>".
8. Select Coding and press the ">>".
9. Memory via radio and code with "F8".

10. Mirror memory function must be selected. Perform coding by pressing "F8".

11. Lock with Safe function must be selected. Perform coding by pressing "F8".

12.  Synchronous mirror adjustment must be selected. Perform coding by pressing "F8".

Removing and Installing Door Unit Carrier|Page 5435 > < Removing and Installing Door Unit Carrier|Page 5433