Convertible Top: Testing and Inspection

6101K2 Calibrating Convertible Top

Preliminary work

Preliminary work for calibration

1. The convertible-top compartment lid drive must be repaired (after an emergency operation).
2. The valve screw of the hydraulic pump must be closed.
3. The engine compartment lid must be closed.
4. The upper microswitches of the left and right rear side section flaps are actuated when the opened convertible top is set down. See under Input

signals in the Tester: Side flap top left or side flap top right. Read out fault memory if necessary and proceed according to the guided
troubleshooting.

5. The lower microswitches of the left and right rear side section flaps are actuated when the convertible top is closed. See under Input signals in the

Tester: Side flap bottom left or side flap bottom right. Read out fault memory if necessary and proceed according to the guided troubleshooting.

6. The convertible top compartment lid microswitch must be unlocked when the convertible top compartment lid is open. See under Input signals in

the Tester: Convertible-top compartment lid released. The microswitch must be locked when the convertible top compartment lid is closed. See
under Input signals in the Tester: Convertible-top compartment lid locked. Read out fault memory if necessary and proceed according to the
guided troubleshooting.

General warning notes

Warning note on calibration

WARNING:

Danger of injury and damage to property.

-

Danger of injury when working on the convertible top.
-

No tools or other items should be stored within the movement range of the convertible top.

-

The movement range of the convertible top and side window must be kept clear.

Calibrating convertible top

Calibration of the Cabriolet convertible top and the convertible top compartment lid is carried out via the diagnosis interface in the car and the PIWIS
Tester. The respective potentiometer values (convertible top and convertible top compartment lid) are established during calibration. If the potentiometer
values are plausible, the values are stored. The calibration values can then be calculated as a percentage by the convertible top control module from the
potentiometer values.

1. Connect the Porsche System Tester to the diagnostic socket.
2. Switch on ignition.
3. Select the Convertible top menu item, Drive links, and select the Calibrate menu item in the command line which then appears.
4. Start calibration with the "F8  key. Calibration can be started irrespective of whether the convertible top position is open or closed.

The latching hook in roof frame -1- does not close during calibration.

Calibration is not counted as actuation. Calibration can be interrupted at any time with the "F8" key on the Tester.