911 Carrera 2 Coupe F6-3600cc 3.6L SOHC (1990)
Blower Motor: Service and Repair
PREPARATION FOR REMOVAL
1. Disconnect battery ground lead.
2. Remove cover of heater/air conditioner (2 screws with washers).
3. Disconnect central electrics.
4. Remove wire harness cover.
5. Lay central electrics aside on the fender (use a fender guard).
6. Pull off electric lead plug on blower final stage.
7. Remove firewall.
Right Blower
1. Disconnect plug T 34 and take plug out of holder.
2. Remove clamps of motor cover and take off cover from above.