9. Place the drainage hose after the pressure regulator into a petrol-resistant container. Make sure that the container does not tip over.

10. Activate the fuel pump relay on the Porsche PIWIS Tester. Press "F8 - Start" until fuel emerges at the drainage hose. Deactivate the fuel pump

relay by pressing "F8 - Stop" and pour any leaked fuel from the container into a petrol-resistant container or into the fuel tank. Keep a stopwatch to
hand for the following measurement.

11. Then, activate the fuel pump relay again by pressing "F8 - Start" and keep it going for 60 seconds. Start the stopwatch at the same time. Collect

emerging fuel in an available container. Deactivate the fuel pump relay after 60 seconds by pressing "F8 - Stop".

12. Pour the collected fuel into the measuring cup and compare the quantity with the vehicle-specific nominal values listed below. Volume: 2.1 l/min.

Volume: 2.0 l/min. Volume: 2.3 l/min Volume: 2.1 l/min.

13. Remove measurement adapter 9705 and attach rapid-action coupling to fuel supply line. Collect escaping fuel. Make sure that the plug-in coupling

is fitted correctly (must engage audibly) by pulling the line apart.

14. Switch off ignition, switch off the Porsche PIWIS Tester and disconnect adapter lead to the vehicle.

Subsequent work for quantity delivered by fuel pump

1. Install underbody covers.