porsche Workshop Repair Guides

Porsche Workshop Service and Repair Manuals

Exhaust Manifold > < Catalytic Converter|Description and Operation|Page 1658
Page 3
background image

1. Grease new clamping sleeve with high-temperature paste and slide it onto the silencer pipe.
2. Insert catalytic converter into the vehicle. When doing so, watch out for the oxygen sensors and cable.

NOTE:  Observe installation position of three-hole flange seal. The beading is facing the exhaust manifold and the edges must not project over the
contour of the flange.

3. Fit new seal and new lock nuts on the exhaust manifold flange and screw on slightly.

4. Slide the clamping sleeve over the silencer pipe and move it to installation position - Installation position of clamping sleeve, then screw on the

two hexagon nuts.

5. Tighten three lock nuts -1- on catalytic converter flange. Tightening torque: 23 (17 ft.lb.) Nm
6. Tighten fastening screws on clamping sleeve. Tightening torque: 23 (17 ft.lb.) Nm
7. Align clamp on catalytic converter holder and tighten M8 screw. Tightening torque: 23 (17 ft.lb.) Nm

Subsequent work

NOTE:

-

Grease the thread of the oxygen sensors that will be fitted again with Optimal Optimally Paste MF.

-

Replace sealing ring. If this is not possible, the "old" oxygen sensor must be tightened to 50 Nm (37 ft.lb.).

1. Install oxygen sensor behind catalytic converter. If the sensor ahead of the catalytic converter was also removed, install this as well.
2. Lay oxygen sensor cable carefully and connect cable plug.
3. Install air cleaner housing.

Exhaust Manifold > < Catalytic Converter|Description and Operation|Page 1658