911 Carrera 4S Cabriolet (997) F6-3.8L (2006)
2. Press in connectors -A- on the control module they engage.
3. Fasten control module with the four fastening screws -1- to the roll-over protection frame.
Subsequent work
Subsequent work on DME control unit
1. Place carpet lining in position, paying attention to the fitted shape.
2. The DME control unit can be programmed using the PIWIS Tester 9718.
Subsequent work for DME control module in Cabriolet
1. Reinstall the carpet over the motor.
2. The DME control unit can be programmed using the PIWIS Tester 9718.
Programming DME control unit
Programming new DME control unit
INFORMATION: Depending on the software version of the PIWIS Tester, a new DME control unit can be asked for the "old DME programming
code". In this case, enter the code from IPAS which is also used for the "new DME programming code".
CAUTION:
Voltage drop
-
Risk of irreparable damage to control unit
-
Risk of damage to control unit
-
Fault entries in the control unit
-
Coding in the control unit is aborted
-
Malfunctions in control unit, even during programming
-
Prior to disconnecting the control unit, switch off the ignition and remove the ignition key.
-
Ensure that the power supply is not interrupted during programming.
-
Connect a battery charger with a current rating of at least - Nominal value: 40 A to the vehicle battery.
INFORMATION:
-
If a new DME control unit is to be installed in a vehicle, the DME code specified in the PPN and the immobiliser code must be entered in the