porsche Workshop Repair Guides

Porsche Workshop Service and Repair Manuals

Relays and Modules - Computers and Control Systems > < Removing and Installing Lambda Sensor Downstream Of Catalytic Converter|Page 1911
Page 3
background image

3. Undo oxygen sensor using an open-ended wrench or open ring wrench (a/f 22) and screw it out by hand -arrow-.

Installing lambda sensor upstream of catalytic converter

Installing oxygen sensor in front of catalytic converter of cylinder bank 1-3

1. Route the oxygen sensors so that the cable can be easily routed from the engine compartment side to the exhaust system.
2. Position the oxygen sensor by hand and screw in as far as possible.

3. Tighten oxygen sensor with commercially available open ring wrench accessory for torque wrench. Open ring wrench angled NR.96-3 and torque

wrench Torque wrench, signal-transmitting with changeover ratchet NR.90 and tighten to the specified tightening torque - Tightening torque: 41
ftlb.±3.5 ftlb
.

4. Route the blue oxygen sensor cable and secure it in the sheetmetal brackets, cable holders, or the cable guide (right side).
5. Connect plug connection (blue cable - black connector) and insert in the holder.

Installing oxygen sensor in front of catalytic converter of cylinder bank 4-6

1. Guide the oxygen sensors through so that the cable can be easily routed from the engine compartment side to the exhaust system.
2. Position the oxygen sensor by hand and screw in as far as possible.
3. Tighten oxygen sensor with commercially available open ring wrench accessory for torque wrench. Open ring wrench angled NR.96-3 and torque

wrench Torque wrench, signal-transmitting with changeover ratchet NR.90 tighten - Tightening torque: 41 ftlb.±3.5 ftlb.

4. Route the blue oxygen sensor cable and secure it in the sheetmetal brackets, cable holders, or the cable guide (right side).
5. Connect plug connection (blue cable - black connector) and insert in the holder.

Subsequent work

Subsequent work for installing oxygen sensors in front of catalytic converter

1. Install air cleaner housing.

Relays and Modules - Computers and Control Systems > < Removing and Installing Lambda Sensor Downstream Of Catalytic Converter|Page 1911