911 Carrera Cabriolet (997) F6-3.6L (2007)
Leak Detection Pump: Service and Repair
Removing And Installing Leakage Diagnosis Pump
Removal
Removing leakage diagnosis pump
1. Unclip sheetmetal clips on the carbon canister -1- with a screwdriver.
2. Carefully open the carbon canister using a rigid spatula or a wide screwdriver. -arrows-
3. Remove active carbon unit and lid.
4. Unscrew Torx screw -1- and pull off air filter.
5. Unscrew three Torx screws -1- used to secure the leakage diagnosis pump -3-.