Leak Detection Pump: Service and Repair

Removing And Installing Leakage Diagnosis Pump

Removal

Removing leakage diagnosis pump

1. Unclip sheetmetal clips on the carbon canister -1- with a screwdriver.

2. Carefully open the carbon canister using a rigid spatula or a wide screwdriver. -arrows-
3. Remove active carbon unit and lid.

4. Unscrew Torx screw -1- and pull off air filter.
5. Unscrew three Torx screws -1- used to secure the leakage diagnosis pump -3-.