911 Carrera Cabriolet (997) F6-3.6L (2007)
Before disconnecting the jump leads, switch on high electrical loads in the recipient vehicle, e.g. rear window heater and interior blower, in order to
reduce any voltage peaks on disconnection. The light must not be turned on.
5. Disconnect the two jump leads in reverse sequence when the engine is running.
Subsequent work
Rework on external power connection, jump lead starting
Jump lead starting:
1. Put on the battery cover and secure by means of the two turn-lock fasteners -A-.
External power connection:
1. Clip in the cover for the fuse carrier.