porsche Workshop Repair Guides

Porsche Workshop Service and Repair Manuals

Cooling System|Capacity Specifications|Page 1712 > < Cooling System|Capacity Specifications|Page 1710
Page 4
background image

Adapter K22 on coolant expansion tank

2. Connect the vacuum pressure gauge of the bleeder tool to the flexible extension. When doing so, ensure that both shut-off valves are closed

(positioned at 90° to flow direction).

3. Connect the Venturi nozzle to the vacuum pressure gauge.

Venturi nozzle on vacuum pressure gauge

Information
^

The quantity of coolant available should exceed the amount required to fill the system by about two liters in order to prevent air being sucked in.

^

An antifreeze content of -35°C corresponds to a mixture of 50:50 (antifreeze: water).

4. Place a canister with a sufficient amount of coolant and with an antifreeze content of -35°C behind the vehicle near to the expansion tank.

Information
^

The bleeding process is completed more quickly if the canister is positioned at the same height as the coolant reservoir.

5. Push the filler hose of the vacuum pressure gauge -5- onto the canister connection. Draw off the return line -6- of the Venturi nozzle into a second

container.

Special canister filling tool

Information

Cooling System|Capacity Specifications|Page 1712 > < Cooling System|Capacity Specifications|Page 1710